8. Fit the lamp stopper [H] to the rear terminal of the new exposure lamp,
and install the lamp.
NOTE: Make sure the stopper fits in the terminal hole [1].
9
Reassemble the 1st scanner.
10
Check the exposure lamp position is correct (see 1-4 Exposure Lamp
Position Adjustment).
NOTE: A stopper is fixed to the exposure lamp in order to prevent possible
lamp rotation.