Manually Deleting Static Route Does Not Affect The Corresponding Slb Entry (7064092); Changing The Default Value For Default-Vlan-Id Could Result In Vlan Misconfiguration (7015004); Some Of The Igmp Conformance Results Don't Match Expectations (7006297 And 6997415); Ports Lock And Corresponding Leds Stay Lit Or Nem Fails To Power On After Doing Consecutive Hardware Resets (6992127) - Oracle Sun Blade 6000 Product Notes

Ethernet switched nem 24p 10gbe release 1.2.2
Table of Contents

Advertisement

Manually Deleting Static Route Does Not Affect
the Corresponding SLB Entry (7064092)
SLB tracks and manages static route entries that correspond to a load balancing group created
by the SLB commands. If a static route entry was created by executing SLB commands, do not
use the no ip route command to remove that static route directly.
Changing the Default Value for default-vlan-id
Could Result in VLAN Misconfiguration (7015004)
Workaround: If you need to change default-vlan-id from 1 (the default value) to some
other value, you must do so before doing any other VLAN configuration. When using XVLAN
features, only default-vlan-id 1 is supported. In order to use the XVLAN feature, you must
restore the default value of 1 for default-vlan-id if it was changed.
Some of the IGMP Conformance Results Don't
Match Expectations (7006297 and 6997415)
The NEM does not fully adhere to the University of New Hampshire (UNH) IGMPv3
Conformance Test Suite.
Workaround: No workaround is available. If you experience a suspected IGMP
interoperability problem or other issue with the NEM, contact your authorized Oracle service
provider.
Ports Lock and Corresponding LEDs Stay Lit or
NEM Fails to Power On After Doing Consecutive
Hardware Resets (6992127)
Workaround: In the unlikely event that the NEM's switch ports lock upon consecutive
hardware resets through CMM, complete these steps:
1. Power off the NEM from CMM: stop /CH/NEMx.
2. Wait five minutes while the capacitance discharges and power the NEM back on:
start /CH/NEMx
3. Remove the NEM, wait five minutes while the capacitance discharges, and reinstall the
NEM in the chassis.