Intel 460GX Software Developer’s Manual page 251

Chipset system
Table of Contents

Advertisement

Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Intel® 460GX Chipset Software Developer's Manual
End OF A20GATE Pass Through Status (A20PTS)–R/WC. This bit is set to 1 to indicate that the
A20GATE pass-through sequence has ended. This bit will only be set if bit 7 of this register is also
set. Software must use the enable bits to determine the exact cause of an SMI#. Software clears
this bit by writing a 1 to it.
Reserved.
USB PIRQ Enable (USBPIRQDEN)–R/W. 1 (default) = USB interrupt is routed to PIRQD. 0 = USB
interrupt does not route to PIRQD. This bit prevents the USB controller from generating an
interrupt. Note that it will probably be configured to generate an SMI using bit 4 of this register.
Default to 1 for compatibility with older USB software.
USB IRQ Status (USBIRQS)–RO. This bit is set to 1 to indicate that the USB IRQ is active.
Software must use the enable bits to determine the exact cause of an SMI#. Writing a 1 to this bit
will have no effect. Software must clear the IRQ via the USB controller.
Trap By 64h Write Status (TBY64W)–R/WC. This bit is set to 1 to indicate that a write to port 64h
occurred. Software must use the enable bits to determine the exact cause of an SMI#. Software
clears this bit by writing a 1 to it.
Trap By 64h Read Status (TBY64R)–R/WC. This bit is set to 1 to indicate that a read to port 64h
occurred. Software must use the enable bits to determine the exact cause of an SMI#. Software
clears this bit by writing a 1 to it.
Trap By 60h Write Status (TBY60W)–R/WC. This bit is set to 1 to indicate that a write to port 60h
occurred. Software must use the enable bits to determine the exact cause of an SMI#. Software
clears this bit by writing a 1 to it.
Trap By 60h Read Status (TBY60R)–R/WC. This bit is set to 1 to indicate that a read to port 60h
occurred. Software must use the enable bits to determine the exact cause of an SMI#. Software
clears this bit by writing a 1 to it.
SMI At End Of Pass Through Enable (SMIEPTE)–R/W. 1=Enable the generation of an SMI when
the A20GATE pass-through sequence has ended. 0 (default) = Disable. This may be required if an
SMI is generated by a USB interrupt in the middle of an A20GATE pass through sequence and
needs to be serviced later.
Pass Through Status (PSS)–RO. 1 =A20GATE pass through sequence is currently in progress. 0
(default) = Not currently executing the A20GATE pass-through sequence. This bit indicates that
the host controller is executing the A20GATE pass-through sequence. If software needs to reset
this bit, it should set Bit 5 to 0 causing the host controller to immediately end the A20GATE pass
through sequence.
A20Gate Pass Through Enable (A20PTEN)–R/W. 1=Enable A20GATE pass through sequence.
0 (default) = Disable. When enabled, the logic will pass through the following A20GATE command
sequence:
Cycle Address Data
Write 64h D1h ( 1 or more) (Starts the Sequence)
Write 60h xxh
Read 64h N/A ( 0 or more)
Write 64h FFh (End of A20GATE Pass Through Sequence)
Any deviation seen in the above sequence will cause the host controller to immediately exit the
sequence and return to typical operation, performing an I/O trap and generating an SMI# if
appropriate enable bits are set.
When enabled, SMI# will not be generated during the sequence, even if the various enable bits are
set. Note that during a Pass-through sequence, the above status bits will not be set for the I/O
accesses that are part of the sequence.
Trap/SMI ON IRQ Enable (USBSMIEN)–R/W. 1 = Enable SMI# generation on USB IRQ. 0
(default) = Disable.
Trap/SMI On 64h Write Enable (64WEN)–R/W. 1 = Enable I/O Trap and SMI# generation on port
64h write. 0 (default) = Disable.
Trap/SMI On 64h Read Enable (64REN)–R/W. 1 = Enable I/O Trap and SMI# generation on port
64h read. 0 (default) = Disable.
Trap/SMI On 60h Write Enable (60WEN)–R/W. 1 = Enable I/O Trap and SMI# generation on port
60h write. 0 (default) = Disable.
Trap/SMI On 60h Read Enable (60REN)–R/W. 1 = Enable I/O Trap and SMI# generation on port
60h read. 0 (default) = Disable.
Universal Serial Bus (USB) Configuration
Description
13-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents