Intel 460GX Software Developer’s Manual page 216

Chipset system
Table of Contents

Advertisement

LPC/FWH Interface Configuration
The Timer Control Word Register specifies the counter selection, the operating mode, the counter
byte programming order and size of the count value, and whether the counter counts down in a 16-
bit or binary-coded decimal (BCD) format. After writing the control word, a new count can be
written at any time. The new value takes effect according to the programmed mode.
Read Back Command
The Read Back Command is used to determine the count value, programmed mode, and current
states of the OUT pin and Null count flag of the selected counter or counters. The Read Back
Command is written to the Timer Control Word Register which latches the current states of the
above mentioned variables. The value of the counter and its status may then be read by I/O access
to the counter address. Note that The Timer Counter Register bit definitions are different during the
Read Back Command than for a normal Timer Counter Register write.
Bit
7:6
5
4
3
2
1
0
Counter Latch Command
Bit
7:6
5:4
3:0
The Counter Latch Command latches the current count value at the time the command is received.
If a Counter is latched once and then, some time later, latched again before the count is read, the
second Counter Latch Command is ignored. The count read will be the count at the time the first
Counter Latch Command was issued. If the counter is programmed for two byte counts, two bytes
must be read. The two bytes do not have to be read successively (read, write, or programming
operations for other counters may be inserted between the reads). Note that the Timer Counter
11-26
Read Back Command. When bits[7:6]=11, the Read Back Command is selected during a write
to the Timer Control Word Register. Following the Read Back Command, I/O reads from the
selected counter's I/O addresses produce the current latch status, the current latched count, or
both if bits 4 and 5 are both 0.
Latch Count of Selected Counters. When bit 5=0, the current count value of the selected
counters will be latched. When bit 5=1, the count will not be latched.
Latch Status of Selected Counters. When bit 4=0, the status of the selected counters will be
latched. When bit 4=1, the status will not be latched.
Counter 2 Select. When bit 3=1, Counter 2 is selected for the latch command selected with bits
4 and 5. When bit 3=0, status and/or count will not be latched.
Counter 1 Select. When bit 2=1, Counter 1 is selected for the latch command selected with bits
4 and 5. When bit 2=0, status and/or count will not be latched.
Counter 0 Select. When bit 1=1, Counter 0 is selected for the latch command selected with bits
4 and 5. When bit 1=0, status and/or count will not be latched.
Reserved. Must be 0.
Counter Selection. Bits 6 and 7 are used to select the counter for latching.
Bit[7:6] Function
00 latch counter 0 select
01 latch counter 1 select
10 latch counter 2 select
11 Read Back Command select
Counter Latch Command. When bits[5:4]=00, the Counter Latch Command is selected during
a write to the Timer Control Word Register. Following the Counter Latch Command, I/O reads
from the selected counter's I/O addresses produce the current latched count.
Reserved. Must be 0.