Hard disk drives / solid state drives
Under no circumstances should you remove an HDD / SSD module
●
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.3.4.1
Preliminary steps
"Locating the defective server" on page 51
Ê
Ê Locate the defective HDD / SSD module as described in section
diagnostic indicators on the front" on page
Only applicable for removing intact HDD / SSD modules:
Ê Before removing a non-defective HDD / SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.3.4.2
Removing a 2.5-inch HDD / SSD module
Ê Remove the HDD / SSD module to be replaced from the server as described
in section
"Removing a 2.5-inch HDD / SSD module" on page
7.3.4.3
Installing a 2.5-inch HDD / SSD module
Ê Install the new HDD / SSD module into the empty drive bay as described in
section
"Installing 2.5-inch HDD / SSD modules" on page 135
7.3.4.4
Concluding steps
"Performing a RAID array rebuild" on page 96
Ê
142
Upgrade and Maintenance Manual