Processors
11.5.2.1 Preparing the heat sink and processor
When installing a new heat sink
Figure 159: Removing the protective heat sink cover
Ê Remove the protective cover from the heat sink.
V
CAUTION!
Ensure not to touch the heat-conductive paste on the bottom of the
heat sink.
When reusing a heat sink
Ê Ensure that all residual thermal paste has been thoroughly cleaned off the
copper surface of the heat sink.
Ê Apply thermal paste to the processor surface as described in section
"Applying thermal paste" on page
288
294.
Upgrade and Maintenance Manual
RX300 S8