Concluding Steps; Removing 2.5-Inch Hdd / Ssd Modules; Preliminary Steps - Fujitsu PRIMERGY RX300 S8 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX300 S8:
Table of Contents

Advertisement

Hard disk drives / solid state drives
Ê Insert the HDD module into a drive bay and carefully push back as far as it
will go (1).
Ê Close the locking lever to lock the hard disk drive in place (2).
7.3.2.4

Concluding steps

"Performing a RAID array rebuild" on page 96
Ê
7.3.3

Removing 2.5-inch HDD / SSD modules

Customer Replaceable Unit
(CRU)
Tools: tool-less
7.3.3.1

Preliminary steps

Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
138
Procedure
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
rebuild" on page
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Performing a RAID array
96.
RX300 S8

Advertisement

Table of Contents
loading