6.2.4

Concluding steps

"Connecting the server to the power source" on page 69
Ê
6.3

Removing a hot-plug power supply unit

Customer Replaceable Unit
(CRU)
Tools: tool-less
I
Note for servers using CMA (Cable Management Arm)
Regarding of removing power supply units, additional tasks are needed,
due to an interference between CMA stopper and the power supply units.
Ê Unlock the CMA stopper.
Ê Remove the CMA stopper with the mounted crossbar.
Ê Support the CMA stopper, the crossbar and the CMA including cables
with your right hand.
Ê Remove the power supply unit and install a dummy cover into the
empty bay.
Ê Remount the complete assembly (CMA stopper, crossbar and CMA)
into the rail.
6.3.1

Preliminary steps

"Locating the defective server" on page 51
Ê
Ê Remove the power cord from the dedicated power supply unit as described
in section
"Disconnecting power cords" on page 54
RX300 S8
Upgrade and Maintenance Manual
Power supply units
Hardware: 5 minutes
107