– Ensure not to damage the EMI springs to comply with applicable
EMC regulations and satisfy cooling requirements and fire
protection measures.
Ê At a slight angle, lower the system board into the chassis.
Ê Carefully shift the system board towards the server rear until the plug shells
engage with the cut-outs in the connector panel (1).
Ê Lower the system board onto the centering bolts (C).
Ensure that the system board is properly seated on both centering bolts.
Figure 289: Securing the system board
Ê Secure the system board with 13 screws (M3 x 6 mm, C26192-Y10-C68)
(see circles).
I
If you want to install a SAS RAID controller, do not insert the screw
markt with (1).
I
Screw torque: 0.6 Nm (not applicable for the Japanese market)
Tighten the screws in a cross diagonal pattern.
Ê Verify the settings on the new system board (see figure
on page
499).
RX300 S8
Upgrade and Maintenance Manual
System board and components
"Onboard settings"