Siren Time; Stray On Ent Dly; Supervision - Abus Secvest 2WAY Installation Instructions Manual

Hide thumbs Also See for Secvest 2WAY:
Table of Contents

Advertisement

Select whether the siren is to start immediately or after the selected delay time
following the triggering of a local or external alarm.

17.10 Siren Time

Select how long the siren should sound when a local or external alarm is triggered.

17.11 Stray on ent dly

Additional delay when the entry delay time is exceeded or the entrance to the property
differs.
Select whether an additional 30 seconds is allowed before an external alarm is
triggered after the delay time is exceeded or a different entrance path is used. If this
function is activated, only an internal alarm is triggered after expiry of the entry delay
time or when other zones are triggered. If this function is deactivated, an internal alarm
is triggered immediately after expiry of the entry delay time or when other zones are
triggered.
This option is used to fulfil the demands listed under guideline EN 50131-1.
When this option is activated, the wireless centre prevents the user from
activating the system when a detector has lost contact with the wireless
centre for more than 15 minutes.

17.12 Supervision

The alarm centre monitors whether the detector is present and active. Wireless
detectors send a message every 10 minutes and WAMs send a message every 4
minutes. When the status message is disabled, the alarm centre is in charge.
When the detector message is lost for more than two hours, then this is classified as
Fault, Tamper or Alarm:
Function
Meaning when system is
activated
Deactivated
No response.
Fault
Fault is reported by telephone.
Tamper
External alarm.
Transmission of supervision
failure and tamper.
Alarm
External alarm.
Transmission of supervision
failure and alarm.
This option is used to fulfil the wireless supervision demands listed under
guideline EN 50131-3.
71
Meaning when system is
deactivated
No response.
Fault is reported on the
display and by signal tone.
Fault is reported on display
and by signal tone.
External alarm.
Transmission of supervision
failure and tamper.
Alarm message on display
and signal tone.