30. Final tasks

Finally, plug the siren plug from the cover of the top part back into the PCB and
replace the tamper contact spring. Make sure that the microphone is also exactly
located in the top part and place the cover back on the top part. Screw the top part
back in place.
Reconnect the battery and loudspeaker cables and the connecting cable between the
base plate and the top part. Place the top part back on to the base plate and tighten
the housing screws.
The ISDN / GSM / ethernet or GPRS module is now operational and is automatically
detected by the wireless alarm centre. You can now start/continue to program the
communication settings. Pay close attention to the setting of the primary transmission
path. If this is set wrongly (e.g. PSTN setting even though no analogue line is
connected), an error message may be displayed such as "Line error" or "Line
transmission error". In this case, check the setting of the primary transmission path and
change it accordingly.

31. Module certification

ISDN, GSM, ethernet and GPRS modules are authorised by postal authorities all over
Europe and conform with the CE according to the 1995/5/EC R&TTE directive. The
manufacturer is in possession of corresponding documents, which can be requested if
necessary.

32. USB port and programming

32.1 Establishing the connection

Use the USB cable to connect the alarm centre to your PC or laptop. Firstly, access
the installer menu on the alarm centre. This prevents a tamper alarm from being
triggered when the top part is removed from the base plate. Loosen the housing
screws on the lower side of the wireless alarm centre as shown in the diagram.
Open the top part, but this time do not loosen the connecting cable from the base
plate. Instead, plug one end of the USB cable into the USB port (1) of the alarm centre.
Connect the other end of the USB cable to your PC or laptop. In the installer menu, go
to "Download" . In the "Download" menu, select "Connection Type".
Select "Local" and press "Select" under the display.
During the initial connection, the alarm centre installs the USB drivers on your
computer. The connection is then established.