16.2 Exit delays of the partition

After entering the exit mode for the partition, a delay time must be entered in the
following cases:
Exit mode = Timed Set or
Exit mode = Silent Set
Select the Ext Time menu point.
After Ext Time has been confirmed with the Select button, the following graphic
display is shown:
Select the corresponding exit time.

16.3 Entry delays of the partition

The entry delay is defined in the same way as the exit delay. Configure the entry delay
time for each exit mode.

16.4 Activating the partition response

Select the corresponding alarm response for the partition in the event of an alarm with
activated partition or system.
Function
Meaning
Local
In the event of an alarm, the internal siren and the
(optional) external siren are activated.
External
In addition to the activation of the local siren, the alarm is
also transmitted by telephone.

16.5 Internal activation of the partition

Each individual partition can also be internally activated. This means that you can
remain in the building without losing all-round protection. With internal activation, some
detectors are not monitored – e.g. motion sensors.
The exit mode for internal activation is programmed in the same way as the exit mode
for normal activation of the partition.

16.6 Behaviour of FE zones at internal activation

It is sometimes important that zones with the entry/exit attribute for normal activation
lose or change this attribute for internal surveillance – for example, a magnetic contact
on the house entrance door. This is usually programmed as an entry/exit zone, and
starts the delay time when the premises are entered. However, if the premises are
activated internally (e.g. at night), it is assumed that nobody will enter via this zone. In
this case, change the zone attribute to "Instant Set" so that an intruder who enters the
house via the entrance door triggers an instant alarm.
Select the relevant alarm response for the partition. The following options are available
as shown in the table 11.
Function
Meaning
Final Exit
The zone also retains its attribute with internally activated
partitions.
Instant Set
The zone changes its attribute to "Instant Set" for
internally activated partitions.
Selection menu for zone behaviour for internally activated partitions

16.7 Behaviour of ER zones at internal activation

The configuration of zone behaviour with the "Entry Route" attribute for
internally activated partitions is made in the same way.