Type
Meaning
Not Used
This output is not in use and is never activated.
(Exception: complete power loss).
Local
This output is activated on local alarms for the defined
siren duration.
E/E Follow
This output is activated for the duration of the delay time
(entry/exit delay active).
Armed Lamp
This output is activated as long as the alarm centre is
internally or externally activated.
24 Hour
This output is activated if a 24-hour zone triggers an
alarm.
Strobe
This output is activated for a local alarm and remains
active until the wireless alarm centre is deactivated.
Strobe Set
This output is activated for approx. 10 seconds following
successful activation of the wireless alarm centre and is
used for acknowledging activation. The function must
also be activated in the partition menu. This output is
also activated for a local alarm and remains active until the
wireless alarm centre is deactivated.
Pulse Set
This output is activated for approx. 1 second following
successful activation of the wireless alarm centre.
Pulse Unset
This output is activated for approx. 1 second following
successful deactivation of the wireless alarm centre as
well as for a panic or fire alarm.
Setting Complete
This output is activated for approx. 10 seconds following
successful activation of the wireless alarm centre.
Siren P1 - P4
This output is activated on local alarms in the selected
partition for the defined siren duration.
Strobe Set P1 - P4
This output is activated for a local alarm in the selected
partition and remains active until the wireless alarm centre
is deactivated. The output is also activated for 10 seconds
after successful activation of the partition.
Technical
This output is activated if a technical zone triggers an
alarm.
Medical
This output is activated if a medical emergency call is
activated.
Panic
This output is activated if a panic alarm is activated.
Fire
This output is activated if a fire alarm is activated.
Zone Follow
This output follows the state of a zone. An overview of
zones is displayed when this type is selected. Select a
corresponding zone.
User Defined
This
zone
components such as remote control units or the code
keypad. The output can also be assigned times at which it
is to be activated and deactivated. If this output type is
selected, the times at which the output is to be activated or
can
be
remote-controlled
by
FullSet RDY P1 - P4
Part Set P1 - P4
Full Set P1 - P4
Select the function User Defined, for example.
End data entry by pressing Back.
various
53
deactivated can be entered at the end (see the note
below).
This output is activated when the partition is ready to be
activated.
This output is activated if a partition is internally activated.
This output is activated if the partition is activated.