8.3 Connections on the base plate of the alarm centre

The following diagram shows the connections on the base plate of the alarm centre.
Number
Description
1
Cable clamp (tension relief) for the 230 V AC mains line
2
Connection socket for the connection cable
3
230 V AC mains connection
4
Connection clamps for wired zones and outputs

8.4 Shutting off unused cable inputs

Use the hole adapter supplied to close off the cable inputs that are not used. Pay
attention to the diagram below:

8.5 Assembling the base plate

Fix the base plate to the wall as shown in the diagram. Ensure that the alarm centre
is installed so that the rear is not screened by hidden metal. Fix the device at a
height where the user can easily read the information on the display.