Accessing The Alarm Centre - Abus Secvest 2WAY Installation Instructions Manual

Hide thumbs Also See for Secvest 2WAY:
Table of Contents

Advertisement

3.5 Accessing the alarm centre

In order to not trigger an alarm when leaving (Ext Time) or entering (Ent Time) the
area, a delay time must be defined for accessing the centre in Partition 01.
Access the installer menu and set the exit or entry delay under the "Partitions" menu
item.
In the installer menu:
menu item.
Select the Partitions
Select Partions 01.
Select the "Name" menu item, then enter a new name for the partition: Ground floor
Select the type: Time
Set 10 seconds for the exit delay time and 120 seconds for the entry delay time.
In our example, the ground floor (Partition 01) is set as follows: Opening detector
OD13-GF-HA
Motion sensor MS4-GF-HA
When the house is exited, the system is activated within 10 seconds.
When returning to the house, you have 120 seconds to disable the system.
Exit = 10 seconds
Entrance = 120 seconds
You must deactivate the system within 120 seconds and may not enter
any other areas where the detectors are not set to Entry Route.
18
Type: Final Exit
Type: Entry Route
MS4-GF-HA
C
OD13-GF-HA