Wam Outputs - Abus Secvest 2WAY Installation Instructions Manual

Hide thumbs Also See for Secvest 2WAY:
Table of Contents

Advertisement

14.7 WAM outputs

In the installer menu:
menu item.
Select the Edit Output
The WAM wireless outputs can be edited after training the WAM as a wireless
transmitter or receiver (function 3).
Please note that the disconnected WAM outputs have a maximum load
of 500 mA at 24 V. This is an opto-isolator with a forward resistance of
2 Ω.
Select output 31 using the arrow keys (WAM 1).
WAM 1 output 1
Edit the menu point under output 31
Select the Name menu item.
Secvest output 31
.
Assign a new name and finish data entry by pressing OK
Select the Type menu item.
An overview of output types can be found in the following table.
Type
Meaning
Not Used
This output is not in use and is never activated. (Exception:
complete power loss).
Local
This output is activated on local alarms for the defined siren
duration.
E/E Follow
This output is activated for the duration of the delay time
(entry/exit delay active).
Armed Lamp
This output is activated as long as the alarm centre is
internally or externally activated.
24 Hour
This output is activated if a 24-hour zone triggers an alarm.
Strobe
This output is activated for a local alarm and remains active
until the wireless alarm centre is deactivated.
Strobe Set
This output is activated for approx. 10 seconds following
successful activation of the wireless alarm centre and is used
for acknowledging activation. The function must also be
activated in the partition menu. This output is also activated
for a local alarm and remains active until the wireless alarm
centre is deactivated.
Pulse Set
This output is activated for approx. 1 second following
successful activation of the wireless alarm centre.
Pulse Unset
This output is activated for approx. 1 second following
successful deactivation of the wireless alarm centre as well as
for a panic or fire alarm.
Setting Complete
This output is activated for approx. 10 seconds following
55
.