To delete the detector and the zone information, select the Default Zone menu item
.
and confirm with Next
.
Confirm deletion by pressing Yes
13.3 Detector already in use
In exceptional cases, the message"Detector already in use" may be
displayed during training of the detector. This occurs after the training
confirmation is received as the detector sends the signal more than
once.
In this case, the display is meaningless.
Checking the detector:
This detector may have already been trained for another zone. Conduct a walk test to
find out which zone this detector has been trained to.
Go to Installer Menu
Test
Walk Test and carry out a walk test by triggering a
tamper contact (T) and an alarm (A).
Some detectors do not have tamper contacts (e.g. smoke detectors)
and only send an alarm (A). The display with the number of tested
zones without tamper contacts remains.
Select Test
Number of zones
to be tested
T and A are displayed next to the trained zone (detector).
13.4 Delete All
Do you want to delete all detectors and zone information?
In the installer menu:
Select the Add/Del Detectors
45
Select Walk Test
T = Tamper
Information:
A = Alarm
All zones tested
Trigger a tamper
contact (T) and
an alarm (A).
menu item.