Siren + Comms: Communication, external sirens, keypads and loudspeakers.
Note that any Siren Delay (see page 50) applies to Siren+Comms, but not Internal or Siren
alarm responses.

7.1.8 Siren Delay

You can use this option to delay the sounding of a confirmed alarm.
If System Options – Confirmation – Sounder On is set to Confirm (see page 55), Siren Delay delays
the sound at keypads and loudspeakers for the specified period after the confirmed alarm.
If System Options – Confirmation – Siren On is set to Confirm (see page 56), Siren Delay delays the
sound at the external siren for the specified period after the confirmed alarm.
The system then operates the siren and sounders for the programmed Siren Time. See also
Sounder and siren operation
"
Note: Siren Delay has no effect if Alarm Response (page 49) is not set to Siren +
Comms, or if a line fault is detected.

7.1.9 Siren Time

This option changes the length of time that the system operates the siren and loudspeakers
during an alarm.
7.1.10 Pt.set Final Exit
Note: This is available only for a part set. This option controls how the system uses
Final Exit zones when the system is part set.
Final Exit: Any zones of type Final Exit with Part Set B, C or D attributes continue to act as Final
Exit zones during part setting.
Normal Alarm: Any zones of type Final Exit with the Part Set B, C or D attributes act as Normal
Alarm zones during part setting.
7.1.11 Pt.set Entry Route
Note: This is available only for a part set. This option controls how the system treats
Entry Route zones when the system is part set.
Entry Route: Any zones of type Entry Route with the Part Set B, C or D attributes continue to act
as Entry Routes zones during part setting.
Final Exit: Any zones of type Entry Route zones with the Part Set B, C or D attributes act as Final
Exit zones during part setting.

7.1.12 Strobe on Set

When set to On, this option causes the panel to activate any output of type Strobe, and the strobe
on any sirens. The outputs/strobes are active for ten seconds after the system sets.

7.1.13 Strobe on Unset

When set to On, this option causes the panel to activate any output of type Strobe, and the strobe
on any sirens. The outputs/strobes are active for ten seconds after the system unsets.
page 55