Partitions; Partition Types - Abus Secvest 2WAY Installation Instructions Manual

Hide thumbs Also See for Secvest 2WAY:
Table of Contents

Advertisement

16. Partitions

In the installer menu:
.
Select Partitions
Select the corresponding function.
For an overview of functions and their attributes, see the table below.
Do not attempt to use a PIR zone as the input or output for a partition.
PIR wireless detectors have an inactive period after each activation to
save battery power. When a partition is activated (or activated
internally), the PIR detector may still be blocked. During this time, no
signal for completion of the activation process can be sent.
Function
Meaning
Name
Select this point to rename a partition. Enter the name in the
same way as for zones or output names.
Type
Select this point to define the output mode of the partition.
Properties of each output mode can be found in the next
section.
Exit Delay
Exit delay times
Entry Delay
Entry delay time
Response
Response in the event of an alarm in this partition.
Part Set
Behaviour of this partition at internal activation (exit delay).
P.Set FE As
Behaviour of entry/exit zone at internal activation. The
options are as follows:
FE as FE –
FE as NA –
10, 20, 30, 45, 60 or 120 sec.
10, 20, 30, 45, 60 or 120 sec.
The entry/exit zone retains the entry/exit
attribute even for internal activation.
The entry/exit zone changes its attribute at
P.Set ER As
Behaviour of the "Entry Route" zone at internal activation
(ER remains ER or ER becomes FE).
Strobe Follow Set
Behaviour of activation acknowledgement. The options are
as follows:
OFF – No visual acknowledgement on external siren after
ON – Visual acknowledgement on external siren after
Strobe Follow Unset
Behaviour of deactivation acknowledgement. Programming
is made in the same way as activation acknowledgement.

16.1 Partition types

Select the corresponding exit mode.
For an overview of exit modes and their attributes, see the table below.
Function
Meaning
Timed Set
The partition is activated following expiry of the defined exit
time.
User Defined
The partition is activated when a zone is closed with the
entry/exit property.
Instant Set
The partition is activated immediately. This exit mode is
recommended for activation over remote control or wireless
cylinders.
Silent Set
Same as the "Timed Set" exit mode, except that no exit signal
can be heard during the delay time.
As Prtn 1
This option is available for partitions 2, 3 and 4. When this
option is selected, the system uses the same type as for
partition 1.
66
internal activation to "Instant Set".
successful activation (not internal).
successful activation (not internal).