14.5 Example: "User Defined" output type

After selecting the User Defined output type and entering the times, you can then
connect the programmed output with a wired input (programmed as "Key Sw
Latched"). In this way, the alarm centre can be activated and deactivated at a defined
time.
In addition, the "User Defined" output can also be remote-controlled. Program the
remote control unit in the user menu under "System -> Remote controls" (see user
manual).

14.6 Adding RF (wireless) outputs

Wireless outputs can be added using a WAM (see "Other devices / Adding WAMs" and
"Editing (WAM) outputs").
In the installer menu:
menu item.
Select the Add Output
The training procedure for the wireless output module is described here (function not
yet available).
Do not add outputs if the WAM (Wireless Accessory Module) is used as
an output module, as this reserves the outputs automatically. Consult
chapter 9.15 (Other devices / Adding WAMs).
Proceed as follows to add a wireless output (not necessary for outputs
on the accessory module):
,
Select (RF)Output 03
for example.
Select SEND to send the learn signal to the receiver.
If the receiver beeps twice, the learn message was correctly received. End the learning
procedure by pressing Yes.
To cancel data entry, press No.
The learn procedure is now started again.
Add another output by pressing Add.
To edit the trained output, press Edit and proceed as detailed in chapter 9.5.1
("Editing outputs").