14. Outputs
The controller has 34 outputs.
The first two outputs (O/P1 and O/P2) are wired outputs.
Outputs 3 to 34 are wireless outputs. They can be accessed using a FU8210
accessory module.
Switch outputs O/P1 and O/P2:
Disconnected, single pole relay contacts
DC: 24 V / 1 A
AC: 120 V / 0.5 A
14.1 Adding outputs
The Secvest has two wire outputs.
Select the Outputs menu item.
Select Add Output.
Select (HW)Output 01
.
Confirm by pressing Yes
Now edit Zone 01.