Jamming; Batt Load Test; Siren In Pset; Force Set - Abus Secvest 2WAY Installation Instructions Manual

Hide thumbs Also See for Secvest 2WAY:
Table of Contents

Advertisement

17.13 Jamming

Select whether the alarm system should display a warning in the case of jamming
detection. If this function is enabled, a warning is shown on the display if jamming is
detected.

17.14 Batt Load Test

Select whether the alarm system should test the battery capacity at every disarming
or every 23 hours. If the function is disabled, the system tests other less important
functions every hour.
When the wireless centre communicates or plays / records a message,
the test is delayed until these activities are finished. If no mains power is
present, the wireless centre makes the test as soon as it is reconnected.

17.15 Siren in PSet

When Activated is selected, the alarm system also starts a local alarm when activated
internally.
When the function is deactivated, only an internal alarm is triggered when the system
is activated internally. When programmed, trans-mission of the alarm to a security
centre (optional) is made every time.

17.16 Force Set

When On is selected, the zones with the "Z" zone attribute are automatically hidden
when the alarm system or partition is activated (provided the zones are open).
When Confirm is selected, the zones with the "Z" zone attribute are automatically
hidden when the alarm system or partition is activated (provided the zones are open).
You must confirm this procedure to activate the system or partition and hide the
zones. Press the active key on the remote control twice.
This setting must not be used when a wireless cylinder is implemented.
When OFF is selected, it is not possible to activate the alarm system or partition
when at least one zone is open, even when this is programmed with the "Z" zone
attribute.
When "Force Set" is activated, the system does not comply to EN50131.

17.17 RF Siren Options

This menu is used to select how the wireless siren responds in case of fire, burglary or
panic alarms. There are two possibilities here:
Siren+Strobe
The siren and strobe are activated by the wireless siren in the event of an alarm.
Strobe
Only the strobe is activated by the wireless siren in the event of an alarm.