21.2 Monitoring Interval

Select the monitoring interval in hours. Within this interval, every detector programmed
for activity monitoring must be triggered at least once to avoid the triggering of a social
care alarm. Select the monitoring interval so that it is within the monitoring
period defined by the monitoring start and end times.
Confirm the chosen interval by pressing OK.

21.3 Set Volume

After a social care alarm is triggered, a voice connection is established over the
telephone (provided this is programmed in the "Social Care" or "Speech Dialler"
settings). If the loudspeaker volume is too low, then it can be changed under "Set
Volume".
After the announcement of the text message, an audio connection is established.
Consult the following table for details on controlling after establishment of the audio
connection. Please remember that an alarm call may need to be confirmed on the
telephone by pressing "5" or "9".

22. Test function

Select the corresponding function. For a list of functions and their attributes, see the
table below.
In the installer menu:
Select the Local menu item.
Function
Meaning
Local
Tests the function of the local sirens in the alarm centre.
Loudspeaker
Tests the function of the local loudspeaker in the alarm
centre.
Keypad
Tests the keypad input function.
Walk Test
Used to go through each trained detector and test its
function.
Detector Signals
Tests the signal strength of the trained detectors.
Ext Sirens
Tests the signal strength of the external sirens.
WAM
Tests the signal strength of the wireless accessory
module.
Arming Station
Tests the signal strength of the arming station.
Outputs
Tests the outputs through manual activation.
Telecommands
Tests the button functions and the owner of the trained
remote control units (telecommands).
Pendants
Tests the function of the emergency call transmitter
(pendant).
PA Detector
Tests the function of the panic detector.
Tag
Tests the function of the chip key (tag).

22.1 Testing the local siren

Activate the siren by pressing On/Off.
After confirming with On/Off, the internal siren is activated. You should now hear the
Talk
Listen
Toggle
End call
Playback home message and alarm
message
Switch off all calls
alarm tone. ON is also shown in the top-right corner of the display.
To stop the test, press the control key under the On/Off display again.
91
DTMF tone "2"
DTMF tone "1"
DTMF tone "*"
DTMF tone "5"
DTMF tone "3"
DTMF tone "9"