22.2 Testing the loudspeaker

Activate the loudspeaker by pressing Play/Stop under the display.
After confirming with Play/Stop, the loudspeaker is activated. You should now hear the
voice messages. You can now listen to all voice messages saved in the display.
Playing is also shown in the top-right corner of the display. The following graphic
display is shown:
To stop the test, press the control key under the Play/Stop display again.

22.3 Testing the keypad

Press all keys on the keypad in succession. Press the double keys simultaneously to
start the test. The corresponding character is shown on the display in response.

22.4 Walk Test

A list of all detectors trained to the system is shown on the display.
Activate all detectors on the premises in succession. If a detector is recognised, the
alarm centre issues a double signal tone. It also shows whether a tamper contact (T)
and/or an alarm (A) is triggered.
The number of zones to be tested (alarm and tamper) is shown at the top of the
display.
After all detectors have been tested, the display shows All Zones tested.
Please note that "24 Hour" and "Fire" zones cannot be tested.

22.5 Detector Signals

Make the detector signal strength test in the same way as the walk test. The signal
strength displayed corresponds to the reception strength of the last received signal of
this detector. For the test, the reception strength of the alarm centre is reduced by 6
dB. The signal strength should be higher than 3 to ensure satisfactory wireless
communication. If the detector signal is too weak, use a repeater (accessory module)
to ensure good wireless communication.

22.6 Ext Sirens

The test of the external siren is used for displaying the signal strength. The signal
strength should be higher than 3.

22.7 WAM Signal

The test of the WAM signal is used for displaying the signal strength. The signal
strength should be higher than 3.
92