ap-detection expire-time <value>
value - The length of time in seconds. Range: 1-604800.
•
Default Setting
3600 s
Command Mode
Radio Interface Configuration
Example
ProCurve Access Point 530(radio1)# ap-detection expire-time
15
ProCurve Access Point 530(radio1)#
ap-detection interval
This command sets the amount of time to wait between scans when
performing periodic (passive) scanning.
Syntax
ap-detection interval <value>
•
value - The length of time in seconds between scans. Range: 10-3600.
Default Setting
10 s
Command Mode
Radio Interface Configuration
Example
ProCurve Access Point 530(radio1)# ap-detection interval 50
ProCurve Access Point 530(radio1)#
ap-detection max-entries
This command sets the maximum amount of AP entries to be saved to the
detected AP list.
Syntax
Command Line Reference
Neighbor AP Detection Commands
9-139