Table 35 :TIMebase Commands Summary (continued)
Command
:TIMebase:VERNier {{0
| OFF} | {1 | ON}}
(see
page
584)
:TIMebase:WINDow:POSi
tion <pos> (see
page
585)
:TIMebase:WINDow:RANG
e <range_value> (see
page
586)
:TIMebase:WINDow:SCAL
e <scale_value> (see
page
587)
Table 36 General :TRIGger Commands Summary
Command
:TRIGger:FORCe (see
page
592)
:TRIGger:HFReject {{0
| OFF} | {1 | ON}}
(see
page
593)
:TRIGger:HOLDoff
<holdoff_time> (see
page
594)
:TRIGger:LEVel:ASETup
(see
page
595)
:TRIGger:LEVel:HIGH
<level>, <source>
(see
page
596)
:TRIGger:LEVel:LOW
<level>, <source>
(see
page
597)
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
Query
:TIMebase:VERNier?
(see
page
584)
:TIMebase:WINDow:POSi
tion? (see
page
585)
:TIMebase:WINDow:RANG
e? (see
page
586)
:TIMebase:WINDow:SCAL
e? (see
page
587)
Query
n/a
:TRIGger:HFReject?
(see
page
593)
:TRIGger:HOLDoff?
(see
page
594)
n/a
:TRIGger:LEVel:HIGH?
<source> (see
page
596)
:TRIGger:LEVel:LOW?
<source> (see
page
597)
Commands Quick Reference
Options and Query Returns
{0 | 1}
<pos> ::= time from the trigger
event to the zoomed view
reference point in NR3 format
<range value> ::= range value in
seconds in NR3 format for the
zoomed window
<scale_value> ::= scale value in
seconds in NR3 format for the
zoomed window
Options and Query Returns
n/a
{0 | 1}
<holdoff_time> ::= 60 ns to 10 s
in NR3 format
n/a
<level> ::= .75 x full-scale
voltage from center screen in NR3
format.
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels)
in NR1 format
<level> ::= .75 x full-scale
voltage from center screen in NR3
format.
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels)
in NR1 format