Sign In
Upload
Manuals
Brands
Hitachi Manuals
Inverter
J100 E4 SERIES
User Manuals: Hitachi J100 E4 SERIES Inverter Drive
Manuals and User Guides for Hitachi J100 E4 SERIES Inverter Drive. We have
1
Hitachi J100 E4 SERIES Inverter Drive manual available for free PDF download: Instruction Manual
Hitachi J100 E4 SERIES Instruction Manual (129 pages)
Brand:
Hitachi
| Category:
Inverter
| Size: 4.79 MB
Table of Contents
Definitions and Symbols
2
Precautions
3
Precautions for EMC - Electro Magnetic Compatibility
4
Appearance and Name of Parts
5
Model Name and Specifications
6
Installation and Wiring
7
Environment Condition
7
Installing the Filter
7
Wiring
8
Signal Wiring
8
Installation and Wiring Diagrams
9
Table of Contents
13
Safety Precautions
14
Input Voltage
14
Installation Locations and Surfaces
14
Motor Terminal Surge Voltage Suppression Filter
16
Protection against Noise Interference from Inverter
16
Effects of Distributor Lines on Inverters
17
Inspection Upon Unpacking
18
Appearance and Names of Parts
19
Installation
20
Wiring the Power Supply and Motor
22
Control Circuit Terminal Diagram
23
Connection to the Programmable Controller
26
Wiring Equipment, Options
27
Terminal
29
Operation
31
Before Starting Operation
31
Test Run
32
Function of Control Circuit Terminal
34
List of Control Circuit Terminals
34
Function Contents of Monitor Terminal
36
Function Contents of Intelligent Input Terminals
37
Example of Output Terminal Connection
38
Terminal Name: External DC Damping (DB)
39
Terminal Name: Initialization (Factory Deliverey State) (STN)
40
Terminal Name: 2Nd Setting Function (SET)
41
Terminal Name: Second Stage Acceleration and Deceleration (2CH)
42
Terminal Name: Free Run Stop (FRS)
43
Terminal Name: External Trip (EXT)
44
Terminal Name: Prevention Function of Restart Upon Power on (USP)
45
Terminal Name: Reset (RS)
46
Terminal Name: Terminal Software Lock (SFT)
47
Terminal Name: Frequency Arrival Signal (AR)
48
Terminal Name: Run Signal (RUN)
49
Terminal Name: Overload Advance Notice Signal (OL)
50
Terminal Name: Alarm Terminal (AL1, AL2-AL0)
51
Operation of the Digital Operator
52
Name of Keys
52
Key Description
53
Explanation of Screen Display
54
Initialization List of Digital Operator
55
Monitor Mode, Function Mode
55
Extension Function Mode
56
Explanation of the Mode
58
Monitor Mode and Function Mode Explanation
58
F1 Running State Monitoring
58
F2 Output Frequency Setting
59
F4 Running Direction Setting
60
F5 V/F Pattern Setting
61
F6 Acceleration Time 1
63
F7 Deceleration Time 1
63
F8 Manual Torque Bost Setting
63
F9 Running Command/Frequency Command Setting
63
F10 Analog Meter Adjustment
64
F11 Motor Receiving Voltage Setting
64
F14 Extended Function Setting
65
Err Trip History Monitor
65
Extension Function Mode Explanation
66
A0 Control Method
66
A1 Motor Capacity
66
A2 Motor Poles Setting
66
M3 Maximum Frequency Adjustment
67
A62 Base Frequency
67
A63 Maximum Frequency Setting
67
A64 Maximum Frequency Switching
67
A4 Start Frequency Adjustment
68
A5/A6 Frequency Upper, Lower Limiter Setting
68
A7/A8/A9 Jump Frequency Setting 1, 2, 3
69
A68 Jump Frequency Range Setting
69
A10 Carrier Frequency Setting
69
A11
70
A12 - A17, A71 Multispeed 1St - 7Th Speed Setting
71
A18/A19 2-Stage Acceleration, Deceleration Time Setting
72
A20 DC Braking Frequency Setting
72
A21 DC Braking Force Adjustment
72
A22 DC Braking Time Adjustment
72
A55 DC Braking On/Off Selection
73
A56 DC Braking Edge/Level Selection
73
A23 Electronic Thermal Level Adjustment
73
A24 Electronic Thermal Characteristic Selection
73
A28 Acceleration, Deceleration (Linear, S-Curve)
74
A30 Overload Signal
74
A31 Overload Limit Level Setting
74
A85 Deceleration Rate Setting for Overload Limit
74
A32 Overload Limit Content Selection
75
A33 LAD Stop Function Setting
75
A34 Trip/Retry Function Selection
75
A35 Trim Ignorance Selection
75
A36 AVR Setting for Deceleration
76
A37 Motor Voltage Setting for Deceleration
76
A38 Dynamic Braking Usage Ratio
76
A39/A40 Optional Arrival Frequency for Acceleration, Deceleration
77
A49 Frequency Arrival Signal Output Method
77
A41 Forward Rotation
77
A42 Reverse Rotation
77
A43 Stop Key On/Off Selection
78
A50 Analog/Digital Meter Selection
78
A51 Frequency Current Monitoring Selection
78
A52 Run Signal Output Selection
78
A53 Enables/Disables Change of Frequency Setting in Soft Lock Status
79
A57 Trip History Clear Selection
79
A58 Reduced Voltage Start Selection
79
A80/A81 Frequency Command Adjust (Voltage, Current)
80
A82, A83 Allowable under Voltage Time
80
A84 Software Lock Selection
81
C0 - C4 Input Terminal Setting 1, 2, 3, 4 and 5
82
C10 Output Terminal Setting
83
C20 Input Terminal a and B Contact Setting
84
C21 Output Terminal a and B Contact Setting
85
Protective Functions
86
Troubleshooting
88
Precautions for Data Setting
90
Maintenance and Inspection - Precautions
91
Inspection Items
91
Recommended Spare Parts
93
Daily Inspection and Periodic Inspection Table
94
Measurement Method for I/O Voltage, Current and Power
97
Parts to be Measured
98
Standard Specifications
99
Output Frequency
102
Measurement Method for Output Voltage
102
Terminal Connection Diagram
103
Dimension Diagram
104
Functions When Using the Optional Remote Operator
106
Connecting the Remote Operator
106
Monitoring Mode Displays When the Remote Operator Is Used
108
Function Mode
109
Function Mode Operation When Using the Remote Operator
114
Protective Function Displayed When Using the Remote Operator
115
Remote Operator/Copy Unit Dimension
116
Copy Unit Function
117
Service
119
For the Digital Operator
120
J100 Series Data Setting Values - for the Remote Operator
123
Capacitor Life Curve
126
Advertisement
Advertisement
Related Products
Hitachi J100U2 SERIES
Hitachi J100-E2 SERIES
Hitachi J1002
Hitachi J100-004SFE2
Hitachi J100-022SFE2
Hitachi J100-015HFE2
Hitachi J100-037HFE2
Hitachi J100-007SFE2
Hitachi J100-015SFE2
Hitachi J100-022HFE2
Hitachi Categories
Projector
Air Conditioner
Drill
Power Tool
TV
More Hitachi Manuals