Maximum Capacity
Hardware Configuration
– Two disk array controllers connected directly to host Fibre Channel adapters
– Six disk enclosures with ten 73 GByte disks each (60 disks total)
– Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
Volume Group Configuration
– Ten RAID 5 volume groups, each comprising six disks (5 data + 1 parity)
– Each disk in a volume group is in a separate enclosure
High Availability
– Handles a single disk failure, single disk enclosure/BCC failure, single channel
failure, or a single controller failure
Disk Capacity
– Maximum capacity 4380 GBytes
– Usable capacity 3650 GBytes