Table 30
Controller Status LEDs codes (cont'd)
Code
Description
0x91
Intermodule error call to flash
function passed bad flash type
0x92
Invalid address in flash device
0x93
Length too long for flash device
0x95
Unable to fully erase boot flash
segments
0x96
Unable to fully erase file flash
segments
0x97
Unable to program boot flash
after 3 cycles of erase and write
0x98
Unable to program application file
flash after 3 cycles of erase and
write
0xA1
Start Boot Firmware
0xA2
Initialize core hardware
0xA3
Determine hardware configuration
0xA4
Determine CDC memory size
0xA5
Determine RAID Parity Assist
memory size
0xA6
Initialize BIOS timer
0xA7
Initialize serial interface
0xA8
General software initialization
0xA9
Display Boot banner
0xAA
Test Boot Menu invocation
0xAA
PCI fatal fault
(steady)
0xAB
Test Boot Menu memory
Comments
Cause / Solution
Firmware file is bad / Download Firmware
with a good file. Attempt to download Firmware
again. If the problem persists, replace the
controller module.
Firmware file is bad / Download Firmware
with a good file. Attempt to download Firmware
again. If the problem persists, replace the
controller module.
Controller module /
reseat or replace
Boot Funct. Status
Boot Funct. Status
Memory problem /
reseat or replace
Controller Enclosure Troubleshooting