Table 30
Controller Status LEDs codes (cont'd)
Code
Description
0xAC
Load Boot Menu
0xAD
Invoke Boot Menu
0xAE
Exit Boot Menu
0xAF
Test Diagnostics Manager
memory
0xB0
Load Diagnostics Manager
0xB1
Invoke Diagnostics Manager
0xB2
Clear work memory
0xB3
Clear extended memory
0xB4
Kernel set-up
0xB5
Enable Level 2 cache
0xB6
Load kernel
0xB7
Load network manager
0xB8
Load Application code symbol
table
0xB9
Invoke kernel
0xBE
Unexpected return from kernel
0xBF
Rebooting after Boot Firmware
download
0xE3
No host channel devices on the
PCI bus
0xE4
Wrong number of drive channel
devices on the PCI bus
0xE5
No RPA device on the PCI bus
Controller Enclosure Troubleshooting
234
Comments
Cause / Solution
Boot Funct. Status
Controller module /
reseat or replace
Memory problem /
reseat or replace
Controller module /
reseat or replace
Controller module /
reseat or replace
Memory problem
Controller module /
reseat or replace
HW Init. status