A controller fault may be due to a failed memory module.
Memory Module Servicing Notes
Memory modules must be serviced by a trained service technician
C
AUTION
ONLY.
Before replacing a failed SIMM or DIMM, remember the following tips:
Always use proper precautions against electrostatic discharge before removing and
handling controller modules, SIMMs, and DIMMs.
Always use the same type and size of memory module to replace a failed module.
The Fault LED on the affected controller module will turn ON if one of its memory
modules fail. This is the same LED used to indicate a controller failure. The controllers
do not contain an LED or other mechanism for identifying individual memory module
failures. The following information should help you determine if the problem is
memory- or controller-related:
Remove the failed controller module and replace a failed memory module while the
other controller module is running.
If cache mirroring is enabled and one controller module fails, the remaining controller
module will assume operation of the disk array, but write cache will be disabled.
Controller Enclosure Troubleshooting