HP Surestore Disk Array 12h - And FC60 Service Manual page 245

Hp surestore e disk array fc60 service manual
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Table 31 Controller Enclosure Troubleshooting Flowchart (Sheet 5 of 5)
E
Is the Fault-A
or Fault-B BBU
LED on?
No
BBU
Full Charge-A
AND
Full Charge-B
LEDs are on?
Yes
BBU status
is good.
Go to
A
The BBU has failed.
Yes
Replace the BBU
Yes
Has the BBU
No
been charging for
7 hours?
1. Faulty Battery charging circuit or
harness
a. Replace both Power Supplies
b. Replace the Battery Harness
2. DOA BBU
3. Midplane
Go to
A
Yes
Has the new
BBU fully charged
in 7 hours?
Wait 7 hours
No
for BBU to fully
charge
Controller Enclosure Troubleshooting
No
245

Advertisement