2. Replacing the Drum Heater
1) Remove the photosensitive drum from the process unit.
2) Remove the two mounting screws
Caution:
Whenever you have removed the photosensitive drum, wrap it with six or more
sheets of copy paper (A3/11" 17") or the drum protection sheet (stored near the
waste toner case) to protect it from soiling and damage.
3) Pull out the flange at the front, and disconnect the connector; then, remove the drum
heater from the photosensitive drum.
3. Installing the Photosensitive Drum
Install the photosensitive drum by reversing the steps used to remove it. During the
work, be sure to take care, avoiding trapping of the cables (drum heater) and dirt or
damage (drum surface).
COPYRIGHT © 1997 CANON INC.
, and remove the flange
Figure 4-314
CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 4 IMAGE FORMATION SYSTEM
at the front.