Removing The Lower Roller; Removing The Upper Separation Claw - Canon NP6251 Service Manual

Hide thumbs Also See for NP6251:
Table of Contents

Advertisement

CHAPTER 6 FIXING SYSTEM
7) Remove the tension spring, and remove the lower separation claw assembly.

13. Removing the Lower Roller

1) Slide out the fixing/feeding unit from the copier.
2) Remove the fixing/feeding assembly front cover.
3) Remove the flywheel.
4) Remove the fixing assembly upper cover and the fixing cleaning belt; then, remove
the silicone oil pan.
5) Remove the upper roller assembly of the fixing assembly.
6) Remove the lower separation claw support plate.
7) Remove the lower roller
the lower roller, and remove the two bearings

14. Removing the Upper Separation Claw

1) Slide out the fixing/feeding unit from the copier.
2) Open the fixing/delivery assembly, and release the spring
separation claw
6-32
COPYRIGHT © 1997 CANON INC.
from the fixing assembly, remove the two E-rings
Figure 6-227
.
Figure 6-228
CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
.
; then, remove the upper