CHAPTER 3 EXPOSURE SYSTEM
3. Basic Sequence of Operations
The distance over which the scanner moves is determined by the microprocessor
based on the copy size, reproduction ratio, and copying mode.
The microprocessor computes the dimensions of the original when determining the
distance over which the scanner moves forward.
Ratio key ON
Scanner motor (M3)
Scanner home
position sensor (PS1)
Scanner original
leading edge 1
sensor (PS3)
Scanner motor drive
signal (M3ON)
Scanner forward
signal (SCFW)
Scanner stop signal
(M3BLK)
Scanning lamp (LA1)
Lens drive motor
(M4, M5)
Blanking exposure
lamp
3-8
COPYRIGHT © 1997 CANON INC.
Copy Start key ON
STBY
INTR
AER
FD RS
*1
*1 Moves the lens according to the selected reproduction ratio and copy size.
*2 The degree of braking may be adjusted in service mode (*3*).
Figure 3-302
CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
SCFW
SCRV
*2 Brake
LSTR
STBY
*2 Brake