Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual page 1383

Fabric manager configuration guide, release 4.x
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Chapter 67
Management Software FAQ
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 67-2
Tooltip
linkFailCreditLoss
linkFailCreditLossB2B
linkFailDebounceTimeout
linkFailLineCardPortShutdown
linkFailLinkReset
linkFailLIPF8Rcvd
linkFailLIPRcvdB2B
linkFailLossOfSignal
linkFailLossOfSync
linkFailLRRcvdB2B
linkFailNOSRcvd
linkFailOLSRcvd
linkFailOPNyRETB2B
linkFailOPNyTMOB2B
linkFailPortInitFail
linkFailPortUnusable
linkFailRxQOverFlow
linkFailTooManyINTR
linkFailure
loopbackDiagFailure
loopbackIsolation
noCommonVsanIsolation
none
nonParticipating
offline
ohmsExtLBTest
other
OL-17256-03, Cisco MDS NX-OS Release 4.x
Device Manager Tooltip Definitions (continued)
Definition
Link failure due to excessive credit loss
indications.
Link failure when link reset (LR) operation fails
due to queue not empty.
Link failure due to re-negotiation failed.
Link failure due to port shutdown.
Link failure due to link reset.
Link failure due to F8 LIP received.
Link failure when loop initialization (LIP)
operation fails due to non empty receive queue.
Link failure due to loss of signal.
Link failure due to loss of sync.
Link failure when link reset (LR) operation fails
due to non-empty receive queue.
Link failure due to non-operational sequences
received.
Link failure due to offline sequences received.
Link failure due to open primitive signal returned
while receive queue not empty.
Link failure due to open primitive signal timeout
while receive queue not empty.
Link failure due to port initialization failure.
Link failure due to port unusable.
Link failure due to receive queue overflow.
Link failure due to excessive port interrupts.
Physical link failure.
Loopback diagnostics failure.
Port is connected to another port in the same
switch.
Trunk is isolated because there are no common
vsans with peer.
No failure.
During loop initialization, the port is not allowed
to participate in loop operations
Physical link is in offline state as defined in the
FC-FS standards.
Link suspended due to external loopback
diagnostics failure.
Undefined reason.
Cisco MDS 9000 Family Fabric Manager Configuration Guide
Other
67-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents