Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual page 1384

Fabric manager configuration guide, release 4.x
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Other
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 67-2
Tooltip
parentDown
peerFCIPPortClosedConnection
peerFCIPPortResetConnection
portBindFailure
portBlocked
portChannelMembersDown
portFabricBindFailure
portGracefulShutdown
portVsanMismatchIsolation
rcfInProgres
srcPortNotBound
suspendedByMode
suspendedBySpeed
suspendedByWWN
swFailure
tooManyInvalidFLOGIs
tovMismatch
trunkNotFullyActive
upgradeInProgress
vsanInactive
vsanMismatchIsolation
zoneMergeFailureIsolation
zoneRemoteNoRespIsolation
Cisco MDS 9000 Family Fabric Manager Configuration Guide
67-18
Device Manager Tooltip Definitions (continued)
Chapter 67
Definition
The physical port to which this interface is bound
is down.
Port went down because peer FCIP port closed
TCP connection.
Port went down because the TCP connection was
reset by the peer FCIP port.
Port got isolated due to port bind failure.
Port blocked due to FICON.
No operational members.
Port isolated due to fabric bind failure.
Port shutdown gracefully.
An attempt is made to connect two switches using
non-trunking ports having different port VSANs.
An isolated xE_port is transmitting a reconfigure
fabric, requesting a disruptive reconfiguration in
an attempt to build a single, non-isolated fabric.
Only the Interconnect_Ports can become isolated.
No source port is specified for this interface.
Port that belongs to a port channel is suspended
due to incompatible operational mode.
Port that belongs to a port channel is suspended
due to incompatible operational speed.
Port that belongs to a port channel is suspended
due to incompatible remote switch WWN.
Software failure.
Suspended due to too many invalid FLOGIs.
Link isolation due to TOV mismatch
Some of the VSANs which are common with the
peer are not up.
Line card upgrade in progress.
Port VSAN is inactive. The port becomes
operational again when the port VSAN is active.
This VSAN is not configured on both sides of a
trunk port.
The two Interconnect_Ports cannot merge zoning
configuration after having exchanged merging
request for zoning.
Isolation due to remote zone server not
responding.
OL-17256-03, Cisco MDS NX-OS Release 4.x
Management Software FAQ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents