Appendix E State and Event Codes
Battery Events
When the battery experiences an event, or a sequence of events, it will change states accordingly. Display texts for
events are transient. Display texts can be viewed at the battery device page only at the time the event is experienced.
Refer to battery states table for troubleshooting.
To view the last known event, logon to the Installer Configuration Tool by accessing the local Wi-Fi signal from the
Generac REbus Beacon. Navigate to 'Battery' then select 'REbus Status.'
Faults: Low = low impact to performance, the device will recover; Med = noticeable impact to performance but still
recoverable; High = high impact to performance or could render device inoperable - device will try to recover.
Errors: Requires manual intervention before device can operate.
Code
Display Text
0x8007
unknown
event
0x800F
unknown
event
0x8011
power up
0x8020
supply under
voltage
0x8030
daily event
0x8040
firmware
received
0x8100
enable
0x8200
disable
0x8220
external estop
0x8300
sysmode
change
0x8330
heartbeat lost
0x8400
unauthorized
sysmode
0x8FE0
SPT error
0x8FF0
hardware
version
mismatch
0x9000
interrupt fault
0xA100
over temp
shutdown
0xA110
fan failure
0xA200
miswiring
150
Table F-6.
Severity
Description
Normal
B-Link microprocessor reset
Fault
B-Link is in undefined state/misconfigured state
(High)
Normal
B-Link powered up
Fault
Power supply measurements were out of range. B- Link will wait for valid power
(Med)
supply voltage to operate.
Normal
Daily event code to show the battery is still communicating
Normal
B-Link received firmware update
Normal
B-Link was enabled
Normal
B-Link was disabled
Normal
B-Link external E-stop was activated
Normal
B-Link sysmode change
Fault
B-Link lost the heartbeat and will not move power until it returns
(Med)
Fault
B-Link current sysmode is invalid
(Med)
Fault
B-Link has mismatched setpoint versions
(Med)
Fault
The hardware version in configuration does not match with the hardware version
(High)
of device firmware.
Fault
False positives may be associated with turning the battery disconnect switch off
(Med)
while running, otherwise may indicate an internal processor issue. Contact
PWRcell Technical Support.
Fault
The B-Link measured a high temperature
(Med)
Fault
The B-Link fan has failed to operate when it should
(Med)
Fault
The B-link noticed an anomaly in voltage/ current measurement compared to its
(Med)
expected wiring state