Generac Power Systems PWRcell X7600 Series Owner's Manual

Generac Power Systems PWRcell X7600 Series Owner's Manual

Hide thumbs Also See for PWRcell X7600 Series:

Advertisement

http://www.generac.com/service-support/product-support-lookup
Para español, visita:
Pour le français, visiter:
SAVE THIS MANUAL FOR FUTURE REFERENCE
Owner's Manual
Generac PWRcell™ Inverter
Loss of life. This product is not intended to
be used in a critical life support application.
Failure to adhere to this warning could result
in death or serious injury.
Register your Generac product at:
https://register.generac.com/
Register your Generac product at:
WWW.GENERAC.COM
http://www.generac.com/service-support/product-support-lookup
WARNING
1-888-GENERAC
(888-436-3722)
1-888-GENERAC
(1-888-436-3722)
009954
(000209b)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PWRcell X7600 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Generac Power Systems PWRcell X7600 Series

  • Page 1 Owner’s Manual Generac PWRcell™ Inverter 009954 WARNING Loss of life. This product is not intended to be used in a critical life support application. Failure to adhere to this warning could result in death or serious injury. (000209b) Register your Generac product at: https://register.generac.com/ 1-888-GENERAC (888-436-3722)
  • Page 2 Use this page to record important information about your Generac Product Serial Number Locations Record the information found on your unit data label on this page. See Independent Authorized Service Dealer (IASD) or Generac Customer Service When contacting an , always supply the complete model number and serial number of the unit.
  • Page 3: Table Of Contents

    Section 1: Introduction and Safety Section 3: Operation Operation and User Interface ........11 Introduction ............1 Home Screen ............11 Read This Manual Thoroughly ........1 Selecting Operational Modes ......11 Safety Rules ............1 How to Obtain Service ..........1 Device Pages ............. 12 Enabling and Disabling Devices ........12 General Hazards ..........2 Mod.
  • Page 4 This page intentionally left blank. Owner’s Manual for Generac PWRcell Inverter...
  • Page 5: Section 1: Introduction And Safety

    Introduction and Safety Section 1: Introduction and Safety Introduction Throughout this publication, and on tags and decals Thank you for purchasing a Generac PWRcell™ Inverter. affixed to the unit, DANGER, WARNING, CAUTION, and The Generac PWRcell Inverter is a storage-ready NOTE blocks are used to alert personnel to special inverter that connects to the Generac PV Link™...
  • Page 6: General Hazards

    Introduction and Safety General Hazards • Connecting Generac PWRcell to the electric utility DANGER grid must only be done after receiving prior approval from the utility company. Automatic start-up. Disconnect utility power and • Only competent, qualified personnel should install, render unit inoperable before working on unit.
  • Page 7: Electrical Hazards

    Introduction and Safety Electrical Hazards Safety Shutdown DANGER DANGER Electrocution. Water contact with a power Electrocution. Initiate a system-wide safety shutdown and turn PWRcell Disconnect Switch OFF on all source, if not avoided, will result in death connected batteries before performing service. Failure or serious injury.
  • Page 8 Introduction and Safety This page intentionally left blank. Owner’s Manual for Generac PWRCell Inverter...
  • Page 9: Section 2: General Information

    General Information Section 2: General Information Specifications Description Units X7600 Series X11400 Series Max. cont. AC power @ 50ºC 11.4 Grid Voltage 120/240 (1-ph) 120/208 (3-ph) Max cont. REbus current (peak) Max cont. grid output current AC terminals wire size 14 to 6 DC terminals wire size 18 to 6...
  • Page 10: Serial Number Location

    General Information Serial Number Location Unit Dimensions Refer to Figure 2-1 to locate unit serial number (A). Record the information from this tag in Table 1: Generac PWRcell Inverter Important Information on the inside front cover of this manual. When requesting assistance, you may be asked to provide this information.
  • Page 11: Component Locations

    General Information Component Locations Figure 2-5. Generac PWRcell is controlled through the Generac PWRcell Inverter control panel. The inverter control panel is used for adjusting system settings and for interacting with devices. LED Indicators Figure 2-5 for LED locations. REbus Status LED REbus Status LED (C) communicates REbus nanogrid status through LED color.
  • Page 12: Operational Modes Overview

    General Information Operational Modes Overview Generac PWRcell offers several operational modes for Some modes interact with Generac PWRcell Batteries to various installation configurations, markets, store power and/or balance production and consumption. applications. Connected REbus devices work together to Table 2-1 Table 2-2 for an overview of available manage the distribution of power based on the selected...
  • Page 13: Priority Backup

    General Information Figure 2-8. When grid service is interrupted, the Figure 2-10. In the event of grid failure, the inverter system enters Islanding mode. In Islanding mode, solar enters Islanding mode. Protected loads are supported by and battery power protected loads. If enough solar power solar and battery power.
  • Page 14: Self Supply Setpoints

    General Information Self Supply Setpoints Figure 2-13. When local demand exceeds available solar-generated power, the battery supplies power to The TargMinImprtP and TargMaxImprtP setpoints allow support local loads. If the building requires more power the building to deliberately import power from the grid than the battery and solar can provide, then the excess within certain limits.
  • Page 15: Section 3: Operation

    Operation Section 3: Operation Operation and User Interface Selecting Operational Modes Once a system is installed, an operational mode that best Figure 3-1. Generac PWRcell is controlled through suits the user’s needs must be set. Once set, the system the Generac PWRcell Inverter control panel. The inverter remains in that mode without needing to be changed.
  • Page 16: Device Pages

    Operation 3. See Figure 3-5. Use the up and down arrows to Enabling and Disabling Devices highlight the desired mode and press the center DANGER button to select it. Electrocution. Initiate a system-wide safety shutdown and turn PWRcell Disconnect Switch OFF on all connected batteries before performing service.
  • Page 17: Mod. Settings Menu

    Operation 4. See Figure 3-9. Highlight Enable and press the NOTE: After selecting Mod. Settings it may take a center button. moment for the settings to load. 3. See Figure 3-12. Use the up and down arrows to scroll through available settings. 4.
  • Page 18: Ethernet Configuration

    Operation Table 3-4. Inverter Device Settings Setpoint Range Default PLM_Channel 0 - 12 TargMaxImprtP|W -30000 to +30000 TargMinImprtP|W -30000 to +30000 EnaIslanding 0 or 1 EnaExtTransfer 0 or 1 ExtTransVolt|V 500-2000 ExtTransTime|s 1-3600 EnaZeroExport 0 or 1 PLM_Disable 0 or 1 CalOverride 0 or 1 CTTurnsRatio...
  • Page 19: Section 4: Maintenance

    Maintenance Section 4: Maintenance Maintenance DANGER Periodically check the intake filter on the bottom of the enclosure to ensure it is not clogged with dust. See Electrocution. Activate safety shutdown before Component Locations for intake filter location. performing emergency or service work. Failure to do so could result in death, serious injury, Clean the filter with a soft brush or vacuum cleaner.
  • Page 20 Maintenance This page intentionally left blank. Owner’s Manual for Generac PWRCell Inverter...
  • Page 21 Maintenance This page intentionally left blank. Owner’s Manual for Generac PWRcell Inverter...
  • Page 22 Maintenance This page intentionally left blank. Owner’s Manual for Generac PWRCell Inverter...
  • Page 24 ©2019 Generac Power Systems, Inc. S45 W29290 Hwy. 59 All rights reserved. Waukesha, WI 53189 Specifications are subject to change without notice. 1-888-GENERAC (1-888-436-3722) No reproduction allowed in any form without prior written www.generac.com consent from Generac Power Systems, Inc.

This manual is also suitable for:

Pwrcell x11400 series

Table of Contents