PWRcell™ Battery State and Event Codes
Valid for HW Versions 1217, 12171 FW Version 12940
Battery States
Display texts for states will be steady and viewable on the PWRcell Battery device page at the inverter control panel,
unless listed below as transient.
Refer to diagnostic procedures in the right most column as necessary. Refer to the PWRcell Battery section of the
PWRcell Diagnostic Repair Manual for detailed descriptions of diagnostic procedures. If unable to resolve functionality,
please call PWRcell Technical Support at 1(855) 635-5186.
Faults: Low = low impact to performance, the device will recover; Med = noticeable impact to performance but still
recoverable; High = high impact to performance or could render device inoperable - device will try to recover.
Errors: Requires manual intervention before device can operate.
Code
Display Text
0x0010
disabled
0x0110
powering up
0x0120
connecting to
REbus
0x0300
standby
0x0310
waiting
0x0330
waiting: no
heartbeat
0x1100
connecting
input
0x6000
charging
0x6040
discharging
0x6300
cell imbalance
0x7000
error
Diagnostic Repair Manual
Transient/
Severity
Steady
Steady
Normal
Transient
Normal
Transient
Normal
Steady
Normal
Transient
Fault
(Med)
Steady
Fault
(Med)
Transient
Normal
Steady
Normal
Steady
Normal
Steady
Fault
(High)
Steady
Error
Table F-5.
Description
B-Link is disabled
B-Link is initializing, or supply
voltage is low
B-Link connecting to REbus
B-Link is connected to REbus but
is not charging/ discharging
B-Link is inhibited
B-Link is inhibited, waiting on
heartbeat
B-Link is connecting input to the
batteries
Battery is charging
Battery is discharging
There is a voltage or temperature
imbalance between the battery
cells
B-Link is in an error state
Appendix E State and Event Codes
Diagnostics
N/A
- If persistent call PWRcell
Technical Support
- If persistent call PWRcell
Technical Support
N/A
- Battery Disconnect Switch
- Battery Fuses
- Battery Power Wiring
- Battery Module CAT5 wiring
- Battery Module Check
- Ensure inverter is enabled
- If persistent call PWRcell
Technical Support
N/A
N/A
- Battery Module Check
- Disable/ Enable
- REbus Power Cycle
- Reference events
149
Need help?
Do you have a question about the PWRcell and is the answer not in the manual?