Goodrive880 Series Inverter Unit Hardware Manual
Note

1.4.3 Maintenance and component replacement

Note

1.4.4 Disposal

202311 (V1.0)
High voltage presents inside the inverter unit during running. Do not carry out any
operation on the inverter unit during running except for keypad setup. The control
terminals of the product form extra-low voltage (ELV) circuits. Therefore, you need
to prevent the control terminals from connecting to accessible terminals of other
devices.
Before turning on the power supply, check the cable connection status.
Prevent anyone from directly touching the energized part of the cabinet door. Pay
special attention to safety when handling shields that are made of metal sheets.
Do not do any withstand voltage testing during unit connection. Disconnect the
motor cable before performing any insulation and voltage withstand tests for the
motor or motor cable.
Do not open the cabinet door since high voltage presents inside the inverter unit
during running.
Do not switch on or switch off the input power supplies of the inverter unit
frequently.
If the inverter unit has been stored for a long time without use, perform checking
and carry out pilot run for the inverter unit before using it again.
Close the inverter unit front cover before running; otherwise, electric shock may
occur.
Only trained and qualified professionals are allowed to perform maintenance,
inspection, and component replacement for the inverter unit.
Cut off all power supplies connected to the inverter unit before terminal wiring, and
wait for at least the time designated on the inverter unit after disconnecting the
power supplies.
During maintenance and component replacement, take measures to prevent
screws, cables and other conductive matters from falling into the internal of the
inverter unit.
Use proper torque to tighten screws.
During maintenance and component replacement, keep the inverter unit and its
parts and components away from combustible materials and ensure they have no
combustible materials adhered.
Do not carry out insulation voltage-endurance test on the inverter unit, or measure
the control circuits of the inverter unit with a megohmmeter.
During maintenance and component replacement, take proper anti-static
measures on the inverter unit and its internal parts.
The inverter unit contains heavy metals. Dispose of a scrap inverter unit as
industrial waste.
Dispose of a scrap product separately at an appropriate collection point but not
place it in the normal waste stream.