Connection And Wiring - Omron V680-CA5D01-V2 User Manual

V680 series rfid system id controller
Hide thumbs Also See for V680-CA5D01-V2:
Table of Contents

Advertisement

SECTION 2
Installation, Connections, and Wiring

Connection and Wiring

Power Supply and Ground Wires
The power supply and ground terminals use M3 self-rising screws. The following type of crimp termi-
nals can be connected to these terminals.
Recommended tightening torque: 0.5 N·m
6.4 max.
For M3 screw)
(
6.4 max.
• Provide 24 VDC to the Controller. The allowable fluctu-
ation in the power supply is 24 VDC ( − 15%/+10%).
• ID Controllers have built-in noise countermeasures
against noise superimposed on the power supply line.
Ground noise can be reduced further by attaching a fil-
ter to the power supply line.
• Twisted-pair wire is recommended for the power line.
• To increase resistance to noise, ground to 100 Ω or
less to an independent ground pole.
• Use a class 2 power supply.
Line filter
+ 24 V
0 V
RFID System
30
User's Manual
Examples of Applicable Crimp Terminals
Manufacturer
Model
1.25-N3A
V1.25-N3A
J.S.T. Mfg. Co., Ltd.
1.25-MS3
V1.25-MS3
Ferrite core
Ground to a resistance of 100 Ω or less
Applicable wire
0.25 to 1.65 mm
2
AWG22 to AWG16
● Recommended Compact DC Power Supply (OMRON)
Model
Output capacity
S8VS-03024
24 VDC, 1.3 A
Note: The maximum power consumption of the Controller is
30 W (1.3 A at 24 VDC). The inrush current, however,
must be considered when selecting the power supply
capacity. A power supply with an output of 1.3 A min. at
24 VDC is recommended.
Type
Forked
Round
Input voltage
100 to 240 VAC

Hide quick links: