SECTION 5
Communications
Parameter data
(when there are changes)
Note 1: Parameters 1, 2, 9, and H are valid only when internal settings are enabled (i.e., when pin 1 on SW3 is ON).
Note 2: The data number of the parameter data is the number specified for the lower digit of the process code.
The settable values for the data number are the same as for the parameter specified by the lower digit of the process
code.
Response
Command
End code
code
S
P
0
2
Parameter data
RFID System
148
User's Manual
Data No. (See note 2.)
"C"
"D"
"E"
"F"
"G"
"H"
Resend flag
Fixed
Parameter data
value
×
×
×
×
0
0
0
2
1
1
1 to 4
Attached only when parameter data is being obtained.
Specify 4 decimal digits. "0000" to "9999" (ms)
"0000": Infinite, Default value: "0500" (ms)
Specify 4 hexadecimal digits. "0001" to "0800" (bytes)
Default value: "0001" (bytes)
"00": No noise detection for communications history (default value)
Noise monitor function disabled.
"01": Noise detection for communications history
Noise monitor function enabled.
"00": Two Output Mode
BUSY, ERROR, OUT1, and OUT2 (default value)
"01": Four Output Mode
OUT1, OUT2, OUT3, and OUT4
Specify 4 decimal digits. "0001" to "0100" (times)
Default value: "0010" (times)
"00": Write protection OFF
"01": Write protection ON (default value)
Terminator
*
CR
2
Settable values