SECTION 2
Installation, Connections, and Wiring
Wiring I/O Lines
Precautions for Reset Signal Input
• Be sure that the input voltage does not exceed the maximum applicable voltage (26.4 V).
The device may malfunction if the rated voltage is exceeded.
• To improve noise resistance, install the input line 1 m or more away from high-voltage devices and
power lines.
Precautions for Error Signal Output
• The maximum switching capacity for the output is 100 mA at 24 VDC ( − 15% to +10%).
Do not use voltages or loads that exceed the switching capacity. Doing so may cause malfunctions.
• Use an auxiliary relay (24 VDC, 100 mA max.) to connect the output circuit.
Pin Arrangement
Pin No.
1
2
3
4
5
6
7
8
9
10
Refer to External I/O Port for details on the external I/O port.
RFID System
32
User's Manual
24 VDC
Name
V600 I/O
V680 I/O
RUN
BUSY
OUT3
ERROR
OUT4
OUT1
OUT2
COM_O
RST
TRG1
TRG2
COM_I
p. 14
Reset input
24 VDC
To error output
• Controller Terminal Arrangement