WRITE REPEAT (RP)
The WRITE REPEAT command is used to execute the most recently executed write command again.
1:1 Protocol
Command
Command
Terminator
code
*
R
P
CR
2
2
Response
Command
End code
Terminator
code
×
×
*
0
0
CR
2
2
2
Command code
End code
Write command information is cleared at the following time.
• When the ID Controller's power supply is reset.
If a WRITE REPEAT command is executed after write command information has been cleared, a command input error
will occur.
The command code is the same as the last write command that was executed.
Indicates the execution result for the command.
"00" indicates a normal end.
Refer to List of End Codes for information on other end codes.
p. 235
SECTION 5
Communications
RFID System
219
User's Manual