SECTION 5
Communications
COMMAND PROCESSING TERMINATE (AA)
The COMMAND PROCESSING TERMINATE command cancels any command except for polling
commands and returns the ID Control to command standby status.
1:1 Protocol
Command
Antenna
designation
Process
Command
desig-
code
nation
0
A
A
2
1
Response
Command
End code
code
×
A
A
2
2
Processing cancel timing
1:N Protocol
Command
Controller No.
×
@
0
1
1
2
Response
Controller No.
×
@
0
1
1
Processing cancel timing
RFID System
142
User's Manual
Terminator
*
1/2
CR
1
2
Resend flag
Processing
Antenna
cancel
desig-
Terminator
timing
nation
*
×
×
0
CR
1/2
0
1
1
2
2
Indicates the timing when polling processing was cancelled.
"00": Command was cancelled before a Tag was detected.
"01": Command was cancelled after a Tag was detected.
Antenna designation
Process
Command
desig-
code
nation
FCS
×
×
×
A
A
0
1/2
2
1
1
2
Resend flag
Antenna
Command
desig-
code
End code
nation
×
×
×
A
A
1/2
0
2
2
2
1
1
Indicates the timing when polling processing was cancelled.
"00": Command was cancelled before a Tag was detected.
"01": Command was cancelled after a Tag was detected.
Terminator
*
CR
2
Processing
cancel timing
FCS
Terminator
×
×
×
*
0
CR
2
2
2