Omron V680-CA5D01-V2 User Manual page 148

V680 series rfid system id controller
Hide thumbs Also See for V680-CA5D01-V2:
Table of Contents

Advertisement

COMMUNICATIONS SET (TR)
The COMMUNICATIONS SET command is used to set serial communications parameters. To use the
ID Controller with the new parameters, either restart the ID Controller or execute the ABORT command
(XZ).
This command is valid only when internal settings are enabled (i.e., when pin 1 on SW3 is ON).
1:1 Protocol
Command
Parity
Baud
Data
Stop
rate
length
bit
desig-
desig-
Command
Terminator
length
nation
nation
code
×
×
×
×
T
R
2
1
1
1
1
Baud rate designation
Data length designation
Parity
Stop bit length
Response
Resend flag
Fixed
Command
value
code
End code
Terminator
0
0
T
R
0
0
2
2
1
1
*
CR
2
Specify the baud rate.
"3": 9,600 bps
"4": 19,200 bps
"5": 38,400 bps
"6": 115,200 bps
Default setting: 9,600 bps
Specify the data length.
"7": 7 bits
"8": 8 bits
Default setting: 7 bits
Specify the type of parity.
"0": None
"1": Odd parity
"2": Even parity
Default setting: Even parity
Specify the number of stop bits.
"1": 1 bit
"2": 2 bits
Default setting: 2 bits
*
CR
2
SECTION 5
Communications
RFID System
145
User's Manual