SECTION 5
Communications
Subcommand
Command
code
P
W C/E
2
1
Query/cancel designation
Antenna designation
Subcommand Response
Command
End code
code
P
W
0
2
End code
RFID System
212
User's Manual
Query/cancel designation
Antenna designation
Terminator
*
1/2
CR
1
2
Specifies querying or canceling polling auto processing.
"C": Processing results query
"E": Processing results cancel
Specifies the Antenna for querying or canceling.
"1": Antenna 1
"2": Antenna 2
Terminator
*
0
CR
2
2
Indicates the execution result for the command.
"00": Normal end
"74": No Tag has approached when polling auto processing results were requested.
"75": No Tag has approached when polling auto processing was cancelled.
"76": Communications processing was in progress or completed when polling auto processing
was cancelled.
Refer to List of End Codes for information on other end codes.
p. 235