Omron V680-CA5D01-V2 User Manual page 163

V680 series rfid system id controller
Hide thumbs Also See for V680-CA5D01-V2:
Table of Contents

Advertisement

SECTION 5
Communications
CONTROLLER CONTROL (CC)
The CONTROLLER CONTROL command is used to manipulate or read I/O.
1:1 Protocol
Command
OUT1
Command
control
code
×
C
C
2
1
OUT1/OUT2 controls
OUT3/OUT4 controls
Response
Command
End code
code
×
C
C
2
TRG1/2 Input status
OUT1/2 Output status
OUT3/4 Output status
RFID System
160
User's Manual
OUT4
OUT2
control
control
OUT3
Terminator
control
×
×
×
*
CR
1
1
1
2
0: Read
1: Turn ON
2: Turn OFF
Output setting: Two Output Mode (BUSY, ERROR, OUT1, and OUT2)
Always "0".
Output setting: Four Output Mode (OUT1, OUT2, OUT3, and OUT4)
0: Read
1: Turn ON
2: Turn OFF
OUT2
Output
TRG2
status
Input status
Resend flag
OUT1
Fixed
TRG1
Output
value
Input status
status
×
0
0
0
0
0
0
2
1
1
1
1
1
1
The current input status
0: OFF
1: ON
The output status of OUT1 and OUT2 after execution.
0: OFF
1: ON
The output status of OUT3 and OUT4 after execution.
• Output setting: Two Output Mode (BUSY, ERROR, OUT1, and OUT2)
X: Fixed
• Output setting: Four Output Mode (OUT1, OUT2, OUT3, and OUT4)
0: OFF
1: ON
OUT4
Output
status
OUT3
Output
status
Terminator
*
0
0
CR
1
2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680-ca5d02-v2

Table of Contents