SECTION 5
Communications
Command List
Commands can be classified into three major types.
Commands for Tag Communications
The following commands are used to communicate with Tags.
Command
code
RD
READ
WT
WRITE
XR
EXPANSION READ
XW
EXPANSION
WRITE
ER
LARGE READ
AR
AUTO READ
AW
AUTO WRITE
DF
DATA FILL
AF
AUTO DATA FILL
CP
COPY
AP
AUTO COPY
PR
POLLING
AUTO READ
PW
POLLING
AUTO WRITE
MD C/K
DATA CHECK
MD S/L
OVERWRITE
COUNT CONTROL
RP
WRITE REPEAT
Communications Subcommands
The following commands are used to cancel command execution.
Command
code
AA
COMMAND PRO-
CESSING TERMI-
NATE
XZ
ABORT
RFID System
176
User's Manual
Name
Reads memory data from the Tag.
Writes data to the memory of the Tag.
Reads up to 2 KB of data from the Tag by dividing the response into frames.
Writes up to 2 KB of data from the Tag by dividing the command into frames.
Reads up to 8 KB of data from a Tag.
Reads data from Tag memory when the Tag approaches.
Writes data to Tag memory when the Tag approaches.
Writes the specified data to the specified number of bytes beginning from the
specified start address.
Writes the specified data to the specified number of bytes beginning from the
specified start address when the Tag approaches.
Reads data from the memory of a Tag using one Antenna and writes it to the
memory of the Tag in the other Antenna's communications area.
Waits for Tags to approach and then reads data from the memory of a Tag using
one Antenna and writes it to the memory of the Tag in the other Antenna's com-
munications area.
Reads data from Tag memory when the Tag approaches. The processing
results can be queried later using a subcommand.
Writes data to Tag memory when the Tag approaches. The processing results
can be queried later using a subcommand.
Checks the memory check code in the Tag.
Used to manage the number of times data is written to a Tag.
Executes the most recently executed write command again.
Name
Forcefully ends communications with a Tag.
Resets the ID Controller to the status entered immediately after turning ON the
power supply. The ID Controller does not send a response. Do not use the
ABORT command while the ID Controller is communicating with a Tag.
Description
Description
Page
p. 178
p. 180
p. 182
p. 186
p. 190
p. 194
p. 196
p. 198
p. 201
p. 203
p. 205
p. 207
p. 211
p. 215
p. 217
p. 219
Page
p. 221
p. 222

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680-ca5d02-v2

Table of Contents